DE-924U Dynamic Signal Test and Analysis System is specially designed for testing the dynamic characteristic of structure, and used for the measurement of various physical quantities such as stress, strain, force, pressure, displacement, velocity, acceleration, temperature. Expanded via Gigabit Ethernet switch, dynamic signals over 1,000 channels can be synchronously tested and analyzed by a single computer.
Dedicated DSP real-time signal processing system per channel
Independent 18-bit SAR A/D converter per channel with sampling rate of up to 1MHz.
DMA for real-time, high speed, stable data transmission.
Built-in bridge completion and excitation
Built-in 24V/4mA biasing circuit, support IEPE sensors.
Built-in low-pass filter and anti-aliasing filter
Suport EID and TEDS
On-site calibration of stress/strain channels is supported to get the current state quickly
Number of Input Channel | 2 channles/card, 8/16 card slots |
Input Coupling | GND, Dif-DC, Sin-DC, AC, Dif-IEPE, Sin-IEPE |
Input Impedance | 30MΩ//100pF |
Full-scale Voltage Value | ±0.005V, ±0.01V, ±0.02V, ±0.05V, ±0.1V, ±0.2V, ±0.5V, ±1.0V, ±2.0V, ±5.0V, 10.0V |
Indication Error | ±0.5% of F.S. |
Stability | <±0.05%/24h |
Nonlinearity | 0.05% of F.S. |
Noise | ≤3μVRMS |
Zero Drift | <3μV/h |
CMV | <±10V@DC ~ 60Hz |
CMR | ≥100dB |
Strain Measurement | |
Full-scale Strain Value | ±1000με, ±10000με, ±100000με |
Indication Error | ≤0.3%red±3με |
Self-Balancing Range | ±20000με |
Bridge Excitation | |
Bridge Configuration | Full, Half, Three-wire quarter bridge |
Bridge Completion Resistors | 120Ω/350Ω (Three-wire quarter bridge) 50Ω ~ 10000Ω (Half bridge / Full bridge) |
Bridge Voltage | 2V, 5V, 10V, 24V DC Within 0.1% |
Current | Max. 50mA |
LPF | |
Cut-off Frequency (-3dB±1dB) | 10Hz, 30Hz, 100Hz, 300Hz, 1kHz, 3kHz, 10kHz, PASS |
Flatness | <0.1dB Within 2/3 of cut-off frequency |
Stop-band Attenuation | - 24dB/Oct. |
HPF | |
Cut-off Frequency (-3dB±1dB) | 0.3Hz, 1Hz, 5Hz, PASS |
Flatness | <0.1dB (Above 2 times cut-off frequency) |
Stop-band Attenuation | ≥-12dB/Oct. |
Communication | Gigabit Ethernet |
A/D Converter | 24 bits |
Freq. Response | DC ~ 100kHz (+0.5dB ~ -3dB) |
Sampling rate | up to 512kHz/channel |
Anti-aliasing filter | |
Filtering Mode | Analog filter and real-time digital filter |
Cut-off Frequency | 1/2.56 of sampling rate |
Stop-band Attenuation | - 120dB |
Flatness | <0.1dB Within analysis frequency range |
Power Supply | 100 ~ 240VAC / 10 ~ 30VDC, 160W (16 channles) / 320W (32 channles) |
Dimensions | |
Semi-19" Chassis | 237×133×338mm |
19" Chassis | 482×133×338mm |
Weight | |
Semi-19" cChassis (16 channels) | Approx. 8kg |
19" Chassis (32 channels) | Approx. 14kg |
Environmental Conditions | |
Operating Temperature | - 10°C to 50°C |
Operating Humidity | 20 ~ 90%RH@40°C |
Storage Temperature | - 40°C to 60°C |
Storage Humidity | 90%RH24h@50°C |
Vibration | Frequency cycle range: 5Hz ~ 55Hz ~ 5Hz Drive amplitude (peak): 0.19mm Sweep frequency: ≤1Oct./min Duration of resonant: 10min Vibration direction: x, y, z |
Figure 1 Single system block diagram
Figure 2 Multi-system block diagram
DE-BPS Basic Platform Software
Running on XP/Win7/Win8/Win10 operating system.
Parameters setting, Function control, Real-time/post-acquisition analysis, data browsing, cursor readouts, scaling curve, data management and simple processing, report generation, long-term continuous data recording, etc..
DE-924U DAQ Card | |
| |
DE-92U Semi-19" Chassis | |
| |
DE-93U 19" chassis | |
| |
DT5857-8 Charge Conditioner (Optional) | |
| |
DT5855-8 Charge Quadratic Integral Conditioner (Optional) | |
Primary integral: 10Hz~10kHz or 1Hz~1kHz Quadratic integral: 10Hz~1kHz or 1Hz~100Hz
Primary integral: <3% Quadratic integral: <5%
| |
DT5856-8 IEPE Quadratic Integral Conditioner (Optional) | |
Primary integral: 10Hz ~ 10kHz or 1Hz ~ 1kHz Quadratic integral: 10Hz ~ 1kHz or 1Hz ~ 100Hz
Primary integral: <3% Quadratic integral: <5%
| |
DT3811-8 Current Loop Conditioner (Optional) | |
| |
DT3814-8 Thermistor Conditioner (Optional) | |
| |
TC-01 Tachometer/Counter Module (Optional) | |
Range: 30 ~ 600000 rpm Accuracy: <0.05%±1r Input signal pulse width: ≥10μs PPR: 1 ~ 4096 Axis ratio: 0.01 ~ 100
Operating mode: support positive/reverse, pulse accumulative count, pulse count per unit time Reset mode: manual/atuomatic Pulse count range: 0 ~ 100k/s
| |
DT5944 Signal Source Output Card (Optional) | |
| |
DT5945 CAN Bus Card (Optional) | |
| |
DT5946 RS485 Communication Card (Optional) | |
| |
DT5947 Digital I/O Card (Optional) | |
|